Chilli Penguin - The Short Penguin
This fiery little 5kW penguin is designed to fit snugly into a builder’s opening but is equally comfortable and utterly sensational free standing. Simple, clean lines, Ecodesign ready, contemporary stainless steel handles, clean burning and highly efficient. This is a stove you will want to come home to.
The Short Penguin Eco is an Ecodesign stove. It uses a combination of three new clean burn features to achieve lower emissions and over 80% efficiency. Secondary heat retaining glazing has been introduced. The combustion air jets have been redesigned and air flow diversion has been introduced.
The combination of these new features mean that the temperatures in the firebox are higher resulting in a more efficient burn of the fuel. In addition the combustion gases remain in these higher temperatures for longer which causes more complete burn of the gases resulting in less harmful emissions and less particulates.
Nominal Output |
Wood 4.8 kW |
Smokeless Fuel 4.9 kW |
Efficiency | 80.6 % | 80.4 % |
Dimensions | ||
Short Penguin | ||
Width 380mm | Depth 367mm | Height 540mm |
Height with plinth | 711mm | |
Multi-fuel | yes | |
Colours available | yes | |
Optional direct air kit available | yes (factory-fitted) | |
Optional plinth available | yes (pre-order) | |
Approved for use in smoke control zones | yes | |
Log length × diameter | length 270mm | diam 100mm |
Flue Collar Diameter | 127mm | |
Flue size required | 125mm | |
Ecodesign measures | ||
Particulates @ 13% O2 | 36 mg/m³ | 15mg/m³ |
CO content @13% O2 | 0.09% | 0.03% |
NOx mg/m³ | 108mg/m³ | 129mg/m³ |
CxHy mg /m³ | 118mg/m³ | 9mg/m³ |
Top Exit | Standard | |
Rear Exit | adaptor required | pre-order |
Distance to combustibles *+ | ||
Side 500mm | Rear 350mm | Above 450mm |
Distance to combustibles with insulated flue fitted to stove top * | ||
Side 500mm | Rear 200mm | Above 450mm |
Distance to non combustibles | ||
Side 100mm | Rear 50mm | Above 150mm |
Hearth Type | no base heat shield/plinth | constructional |
Hearth type | with base heat shield /plinth | 12mm |
* these are the minimum distances, be aware that there are other considerations eg. access for sweeping, height of kettle etc | ||
+ if single wall ie. non insulated flue is used then the distance to combustibles at the rear is equal to 3 x flue diameter |