Chilli Penguin - The Stock Cube
This penguin is clear, determined, honest and single minded. It doesn’t compromise, it is a wood burner only. It is built to be strong, simple, efficient and clean burning. If you want a 5kW wood burner, squarer and deeper than our Woody.. this could be your penguin. This penguin will be a true and honest friend, to warm you on those Chilli winter nights.
The Stock Cube is a wood only stove. The wood sits right on the vermiculite bricks on the base of the stove, there is no need for a grate. It has a generous fire box, sized for logs 300mm long and an even more generous piece of glass, offering you a wonderful clear view of the roaring fire. The efficiency is 76.9%. It is an Eco design stove, suitable for use in smoke control zones. There is a convection panel option available for this stove, called the Stock Cube convector
Wood ONLY.
| Nominal output | 4.8 kW | |
| Efficiency | 76.9 % | |
| Dimensions | ||
| Stock Cube | ||
| Width 475 mm | Depth 405 mm | Height 583 mm |
| Wood only | yes | |
| Colours available | yes | |
| Optional Direct Air Kit | yes (retrofittable) | |
| Optional plinth | yes | |
| Approved for use in smoke control zones | yes | |
| Log length × diameter | length 300mm | diam 100mm |
| Flue collar diameter | 127mm | |
| Flue size required | min 125mm | |
| Ecodesign measures | ||
| Particulates @ 13% O2 | 27 mg/m³ | |
| CO content @13% O2 | 0.12 % | |
| NOx mg/m³ | 114 mg/m³ | |
| CxHy mg /m³ | 116 mg/m³ | |
| Top Exit | standard | |
| Rear Exit | fit blanking plate to top exit | |
| option for rear flue only (no top hole) can be selected at point of order | ||
| Distance to combustibles *+ | ||
| side 500mm | rear 400mm | above 500mm |
| Distance to combustibles with insulated flue fitted to stove top * | ||
| side 500mm | rear 150mm | above 500mm |
| Distance to non combustibles | ||
| side 100mm | rear 50mm | above 150mm |
| Hearth type | 12mm | |
| * these are the minimum distances, be aware that there are other considerations eg. access for sweeping, height of kettle etc | ||
| + if single wall ie. non insulated flue is used then the distance to combustibles at the rear is equal to 3 x flue diameter | ||